fully-threaded screws Search Results


90
DePuy Synthes antegrade 4.5-mm fully threaded screws
Antegrade 4.5 Mm Fully Threaded Screws, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/antegrade 4.5-mm fully threaded screws/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
antegrade 4.5-mm fully threaded screws - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes fully-threaded screws
Fully Threaded Screws, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fully-threaded screws/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
fully-threaded screws - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Bionx Implants Inc bioabsorbable noncannulated fully threaded 4.5-mm self-reinforced polylactide (sr-plla) screw
Bioabsorbable Noncannulated Fully Threaded 4.5 Mm Self Reinforced Polylactide (Sr Plla) Screw, supplied by Bionx Implants Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/bioabsorbable noncannulated fully threaded 4.5-mm self-reinforced polylactide (sr-plla) screw/product/Bionx Implants Inc
Average 90 stars, based on 1 article reviews
bioabsorbable noncannulated fully threaded 4.5-mm self-reinforced polylactide (sr-plla) screw - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Axomed GmbH 4.5 × 70 mm titanium retrograde transpubic screw
Exemplified specimens from the 5 study groups instrumented with ( A ) group 1: SI screw (1); ( B ) group 2: SI screw (1) plus supra-acetabular external fixator (2); ( C ) group 3: SI screw (1) plus plate fixation (3); ( D ) group 4: SI screw (1) plus <t>retrograde</t> <t>transpubic</t> screw (4); ( E ) group 5: S1/S2 ala–ilium screws (5).
4.5 × 70 Mm Titanium Retrograde Transpubic Screw, supplied by Axomed GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/4.5 × 70 mm titanium retrograde transpubic screw/product/Axomed GmbH
Average 90 stars, based on 1 article reviews
4.5 × 70 mm titanium retrograde transpubic screw - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
NuVasive Inc polyaxial pedicle screws with a cobalt chrome head and titanium alloy shaft (ti-6a1–4 v)
Exemplified specimens from the 5 study groups instrumented with ( A ) group 1: SI screw (1); ( B ) group 2: SI screw (1) plus supra-acetabular external fixator (2); ( C ) group 3: SI screw (1) plus plate fixation (3); ( D ) group 4: SI screw (1) plus <t>retrograde</t> <t>transpubic</t> screw (4); ( E ) group 5: S1/S2 ala–ilium screws (5).
Polyaxial Pedicle Screws With A Cobalt Chrome Head And Titanium Alloy Shaft (Ti 6a1–4 V), supplied by NuVasive Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/polyaxial pedicle screws with a cobalt chrome head and titanium alloy shaft (ti-6a1–4 v)/product/NuVasive Inc
Average 90 stars, based on 1 article reviews
polyaxial pedicle screws with a cobalt chrome head and titanium alloy shaft (ti-6a1–4 v) - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes quadricortical, fully threaded syndesmotic screw
Exemplified specimens from the 5 study groups instrumented with ( A ) group 1: SI screw (1); ( B ) group 2: SI screw (1) plus supra-acetabular external fixator (2); ( C ) group 3: SI screw (1) plus plate fixation (3); ( D ) group 4: SI screw (1) plus <t>retrograde</t> <t>transpubic</t> screw (4); ( E ) group 5: S1/S2 ala–ilium screws (5).
Quadricortical, Fully Threaded Syndesmotic Screw, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/quadricortical, fully threaded syndesmotic screw/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
quadricortical, fully threaded syndesmotic screw - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes fully threaded cortical screw 414-850s
Exemplified specimens from the 5 study groups instrumented with ( A ) group 1: SI screw (1); ( B ) group 2: SI screw (1) plus supra-acetabular external fixator (2); ( C ) group 3: SI screw (1) plus plate fixation (3); ( D ) group 4: SI screw (1) plus <t>retrograde</t> <t>transpubic</t> screw (4); ( E ) group 5: S1/S2 ala–ilium screws (5).
Fully Threaded Cortical Screw 414 850s, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fully threaded cortical screw 414-850s/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
fully threaded cortical screw 414-850s - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes fully threaded transiliosacral screw
( A ) Schematic drawing of the triangular fixation of the sacrum. Two oblique screws in the S1 vertebra and a <t>transiliosacral</t> screw in the S2 vertebra. ( B ) Schematic drawing of the additional cement augmentation of the oblique screws in the S1 vertebra. Dotted red line represents the fracture-lines.
Fully Threaded Transiliosacral Screw, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fully threaded transiliosacral screw/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
fully threaded transiliosacral screw - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes fully threaded self-tapping stainless steel cannulated sacro-iliac (si) screws
( A ) Schematic drawing of the triangular fixation of the sacrum. Two oblique screws in the S1 vertebra and a <t>transiliosacral</t> screw in the S2 vertebra. ( B ) Schematic drawing of the additional cement augmentation of the oblique screws in the S1 vertebra. Dotted red line represents the fracture-lines.
Fully Threaded Self Tapping Stainless Steel Cannulated Sacro Iliac (Si) Screws, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fully threaded self-tapping stainless steel cannulated sacro-iliac (si) screws/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
fully threaded self-tapping stainless steel cannulated sacro-iliac (si) screws - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
DePuy Synthes polyaxial, dual-lead threaded, and fully cannulated screw with three fenestrations in the distal tip
( A ) Schematic drawing of the triangular fixation of the sacrum. Two oblique screws in the S1 vertebra and a <t>transiliosacral</t> screw in the S2 vertebra. ( B ) Schematic drawing of the additional cement augmentation of the oblique screws in the S1 vertebra. Dotted red line represents the fracture-lines.
Polyaxial, Dual Lead Threaded, And Fully Cannulated Screw With Three Fenestrations In The Distal Tip, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/polyaxial, dual-lead threaded, and fully cannulated screw with three fenestrations in the distal tip/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
polyaxial, dual-lead threaded, and fully cannulated screw with three fenestrations in the distal tip - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Medtronic Sofamor Danek 3.5-mm lag or fully threaded universal cannulated screw
( A ) Schematic drawing of the triangular fixation of the sacrum. Two oblique screws in the S1 vertebra and a <t>transiliosacral</t> screw in the S2 vertebra. ( B ) Schematic drawing of the additional cement augmentation of the oblique screws in the S1 vertebra. Dotted red line represents the fracture-lines.
3.5 Mm Lag Or Fully Threaded Universal Cannulated Screw, supplied by Medtronic Sofamor Danek, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/3.5-mm lag or fully threaded universal cannulated screw/product/Medtronic Sofamor Danek
Average 90 stars, based on 1 article reviews
3.5-mm lag or fully threaded universal cannulated screw - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
Bionx Implants Inc fully threaded bioabsorbable self-reinforced polylactide screw in diameter and 22-mm long
( A ) Schematic drawing of the triangular fixation of the sacrum. Two oblique screws in the S1 vertebra and a <t>transiliosacral</t> screw in the S2 vertebra. ( B ) Schematic drawing of the additional cement augmentation of the oblique screws in the S1 vertebra. Dotted red line represents the fracture-lines.
Fully Threaded Bioabsorbable Self Reinforced Polylactide Screw In Diameter And 22 Mm Long, supplied by Bionx Implants Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fully threaded bioabsorbable self-reinforced polylactide screw in diameter and 22-mm long/product/Bionx Implants Inc
Average 90 stars, based on 1 article reviews
fully threaded bioabsorbable self-reinforced polylactide screw in diameter and 22-mm long - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

Image Search Results


Exemplified specimens from the 5 study groups instrumented with ( A ) group 1: SI screw (1); ( B ) group 2: SI screw (1) plus supra-acetabular external fixator (2); ( C ) group 3: SI screw (1) plus plate fixation (3); ( D ) group 4: SI screw (1) plus retrograde transpubic screw (4); ( E ) group 5: S1/S2 ala–ilium screws (5).

Journal: Journal of Clinical Medicine

Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring

doi: 10.3390/jcm10112326

Figure Lengend Snippet: Exemplified specimens from the 5 study groups instrumented with ( A ) group 1: SI screw (1); ( B ) group 2: SI screw (1) plus supra-acetabular external fixator (2); ( C ) group 3: SI screw (1) plus plate fixation (3); ( D ) group 4: SI screw (1) plus retrograde transpubic screw (4); ( E ) group 5: S1/S2 ala–ilium screws (5).

Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm titanium retrograde transpubic screw (Axomed GmbH).

Techniques:

Creation of customised PMMA guides for predrilling of the external fixator, retrograde transpubic screw, and S1/S2 ala–ilium screw fixation.

Journal: Journal of Clinical Medicine

Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring

doi: 10.3390/jcm10112326

Figure Lengend Snippet: Creation of customised PMMA guides for predrilling of the external fixator, retrograde transpubic screw, and S1/S2 ala–ilium screw fixation.

Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm titanium retrograde transpubic screw (Axomed GmbH).

Techniques:

Customised PMMA guide for predrilling of the retrograde transpubic screw.

Journal: Journal of Clinical Medicine

Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring

doi: 10.3390/jcm10112326

Figure Lengend Snippet: Customised PMMA guide for predrilling of the retrograde transpubic screw.

Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm titanium retrograde transpubic screw (Axomed GmbH).

Techniques:

Outcome measures for axial stiffness and cycles to failure.

Journal: Journal of Clinical Medicine

Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring

doi: 10.3390/jcm10112326

Figure Lengend Snippet: Outcome measures for axial stiffness and cycles to failure.

Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm titanium retrograde transpubic screw (Axomed GmbH).

Techniques:

Outcome measures for displacement at the fracture sites, shown in terms of median and interquartile range (IQR).

Journal: Journal of Clinical Medicine

Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring

doi: 10.3390/jcm10112326

Figure Lengend Snippet: Outcome measures for displacement at the fracture sites, shown in terms of median and interquartile range (IQR).

Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm titanium retrograde transpubic screw (Axomed GmbH).

Techniques:

Boxplots showing initial axial stiffness slope. 1: Sacroiliac (SI) screw; 2: SI screw plus supra-acetabular external fixator; 3: SI screw plus anterior plate; 4: SI screw plus retrograde transpubic screw; 5: S1/S2 ala–ilium screws. Asterisks above the boxplots indicate significant differences.

Journal: Journal of Clinical Medicine

Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring

doi: 10.3390/jcm10112326

Figure Lengend Snippet: Boxplots showing initial axial stiffness slope. 1: Sacroiliac (SI) screw; 2: SI screw plus supra-acetabular external fixator; 3: SI screw plus anterior plate; 4: SI screw plus retrograde transpubic screw; 5: S1/S2 ala–ilium screws. Asterisks above the boxplots indicate significant differences.

Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm titanium retrograde transpubic screw (Axomed GmbH).

Techniques:

Boxplots showing cycles to failure. 1: Sacroiliac (SI) screw; 2: SI screw plus supra-acetabular external fixator; 3: SI screw plus anterior plate; 4: SI screw plus retrograde transpubic screw; 5: S1/S2 ala–ilium screws. Asterisks above the boxplots indicate significant differences.

Journal: Journal of Clinical Medicine

Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring

doi: 10.3390/jcm10112326

Figure Lengend Snippet: Boxplots showing cycles to failure. 1: Sacroiliac (SI) screw; 2: SI screw plus supra-acetabular external fixator; 3: SI screw plus anterior plate; 4: SI screw plus retrograde transpubic screw; 5: S1/S2 ala–ilium screws. Asterisks above the boxplots indicate significant differences.

Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm titanium retrograde transpubic screw (Axomed GmbH).

Techniques:

Failure modes (red circle) in groups 1 (SI screw) ( A ), 2 (SI screw plus supra-acetabular external fixator) ( B ), 3 (SI screw plus plate fixation) ( C ), 4 (SI screw plus a retrograde transpubic screw) ( D ), and 5 (S1/S2 ala–ilium screws) ( E ) after reaching test stop criterion of 30 mm machine actuator displacement.

Journal: Journal of Clinical Medicine

Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring

doi: 10.3390/jcm10112326

Figure Lengend Snippet: Failure modes (red circle) in groups 1 (SI screw) ( A ), 2 (SI screw plus supra-acetabular external fixator) ( B ), 3 (SI screw plus plate fixation) ( C ), 4 (SI screw plus a retrograde transpubic screw) ( D ), and 5 (S1/S2 ala–ilium screws) ( E ) after reaching test stop criterion of 30 mm machine actuator displacement.

Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm titanium retrograde transpubic screw (Axomed GmbH).

Techniques:

( A ) Schematic drawing of the triangular fixation of the sacrum. Two oblique screws in the S1 vertebra and a transiliosacral screw in the S2 vertebra. ( B ) Schematic drawing of the additional cement augmentation of the oblique screws in the S1 vertebra. Dotted red line represents the fracture-lines.

Journal: Journal of Clinical Medicine

Article Title: Triangular Screw Placement to Treat Dysmorphic Sacral Fragility Fractures in Osteoporotic Bone Results in an Equivalent Stability to Cement-Augmented Sacroiliac Screws—A Biomechanical Cadaver Study

doi: 10.3390/jcm14051497

Figure Lengend Snippet: ( A ) Schematic drawing of the triangular fixation of the sacrum. Two oblique screws in the S1 vertebra and a transiliosacral screw in the S2 vertebra. ( B ) Schematic drawing of the additional cement augmentation of the oblique screws in the S1 vertebra. Dotted red line represents the fracture-lines.

Article Snippet: Group 1: In this group, we stabilized the sacral fracture using two partially threaded sacroiliac screws from both sides, oblique inverted (cannulated, partial threaded steel screw 7.3 mm, DePuy Synthes, Raynham, MA, USA), and a fully threaded transiliosacral screw (cannulated, fully threaded steel screw 7.3 mm, DePuy Synthes, Raynham, MA, USA), which led to a total of 6 cortical index osteosynthesis procedures of groups 1 and 2 together ( A).

Techniques: