DePuy Synthes
antegrade 4.5-mm fully threaded screws Antegrade 4.5 Mm Fully Threaded Screws, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/antegrade 4.5-mm fully threaded screws/product/DePuy Synthes Average 90 stars, based on 1 article reviews
antegrade 4.5-mm fully threaded screws - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
fully-threaded screws Fully Threaded Screws, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/fully-threaded screws/product/DePuy Synthes Average 90 stars, based on 1 article reviews
fully-threaded screws - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Bionx Implants Inc
bioabsorbable noncannulated fully threaded 4.5-mm self-reinforced polylactide (sr-plla) screw Bioabsorbable Noncannulated Fully Threaded 4.5 Mm Self Reinforced Polylactide (Sr Plla) Screw, supplied by Bionx Implants Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/bioabsorbable noncannulated fully threaded 4.5-mm self-reinforced polylactide (sr-plla) screw/product/Bionx Implants Inc Average 90 stars, based on 1 article reviews
bioabsorbable noncannulated fully threaded 4.5-mm self-reinforced polylactide (sr-plla) screw - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Axomed GmbH
4.5 × 70 mm titanium retrograde transpubic screw ![]() 4.5 × 70 Mm Titanium Retrograde Transpubic Screw, supplied by Axomed GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/4.5 × 70 mm titanium retrograde transpubic screw/product/Axomed GmbH Average 90 stars, based on 1 article reviews
4.5 × 70 mm titanium retrograde transpubic screw - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
NuVasive Inc
polyaxial pedicle screws with a cobalt chrome head and titanium alloy shaft (ti-6a1–4 v) ![]() Polyaxial Pedicle Screws With A Cobalt Chrome Head And Titanium Alloy Shaft (Ti 6a1–4 V), supplied by NuVasive Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/polyaxial pedicle screws with a cobalt chrome head and titanium alloy shaft (ti-6a1–4 v)/product/NuVasive Inc Average 90 stars, based on 1 article reviews
polyaxial pedicle screws with a cobalt chrome head and titanium alloy shaft (ti-6a1–4 v) - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
quadricortical, fully threaded syndesmotic screw ![]() Quadricortical, Fully Threaded Syndesmotic Screw, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/quadricortical, fully threaded syndesmotic screw/product/DePuy Synthes Average 90 stars, based on 1 article reviews
quadricortical, fully threaded syndesmotic screw - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
fully threaded cortical screw 414-850s ![]() Fully Threaded Cortical Screw 414 850s, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/fully threaded cortical screw 414-850s/product/DePuy Synthes Average 90 stars, based on 1 article reviews
fully threaded cortical screw 414-850s - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
fully threaded transiliosacral screw ![]() Fully Threaded Transiliosacral Screw, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/fully threaded transiliosacral screw/product/DePuy Synthes Average 90 stars, based on 1 article reviews
fully threaded transiliosacral screw - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
fully threaded self-tapping stainless steel cannulated sacro-iliac (si) screws ![]() Fully Threaded Self Tapping Stainless Steel Cannulated Sacro Iliac (Si) Screws, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/fully threaded self-tapping stainless steel cannulated sacro-iliac (si) screws/product/DePuy Synthes Average 90 stars, based on 1 article reviews
fully threaded self-tapping stainless steel cannulated sacro-iliac (si) screws - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
polyaxial, dual-lead threaded, and fully cannulated screw with three fenestrations in the distal tip ![]() Polyaxial, Dual Lead Threaded, And Fully Cannulated Screw With Three Fenestrations In The Distal Tip, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/polyaxial, dual-lead threaded, and fully cannulated screw with three fenestrations in the distal tip/product/DePuy Synthes Average 90 stars, based on 1 article reviews
polyaxial, dual-lead threaded, and fully cannulated screw with three fenestrations in the distal tip - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Medtronic Sofamor Danek
3.5-mm lag or fully threaded universal cannulated screw ![]() 3.5 Mm Lag Or Fully Threaded Universal Cannulated Screw, supplied by Medtronic Sofamor Danek, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/3.5-mm lag or fully threaded universal cannulated screw/product/Medtronic Sofamor Danek Average 90 stars, based on 1 article reviews
3.5-mm lag or fully threaded universal cannulated screw - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Bionx Implants Inc
fully threaded bioabsorbable self-reinforced polylactide screw in diameter and 22-mm long ![]() Fully Threaded Bioabsorbable Self Reinforced Polylactide Screw In Diameter And 22 Mm Long, supplied by Bionx Implants Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/fully threaded bioabsorbable self-reinforced polylactide screw in diameter and 22-mm long/product/Bionx Implants Inc Average 90 stars, based on 1 article reviews
fully threaded bioabsorbable self-reinforced polylactide screw in diameter and 22-mm long - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Journal of Clinical Medicine
Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring
doi: 10.3390/jcm10112326
Figure Lengend Snippet: Exemplified specimens from the 5 study groups instrumented with ( A ) group 1: SI screw (1); ( B ) group 2: SI screw (1) plus supra-acetabular external fixator (2); ( C ) group 3: SI screw (1) plus plate fixation (3); ( D ) group 4: SI screw (1) plus retrograde transpubic screw (4); ( E ) group 5: S1/S2 ala–ilium screws (5).
Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm
Techniques:
Journal: Journal of Clinical Medicine
Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring
doi: 10.3390/jcm10112326
Figure Lengend Snippet: Creation of customised PMMA guides for predrilling of the external fixator, retrograde transpubic screw, and S1/S2 ala–ilium screw fixation.
Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm
Techniques:
Journal: Journal of Clinical Medicine
Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring
doi: 10.3390/jcm10112326
Figure Lengend Snippet: Customised PMMA guide for predrilling of the retrograde transpubic screw.
Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm
Techniques:
Journal: Journal of Clinical Medicine
Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring
doi: 10.3390/jcm10112326
Figure Lengend Snippet: Outcome measures for axial stiffness and cycles to failure.
Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm
Techniques:
Journal: Journal of Clinical Medicine
Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring
doi: 10.3390/jcm10112326
Figure Lengend Snippet: Outcome measures for displacement at the fracture sites, shown in terms of median and interquartile range (IQR).
Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm
Techniques:
Journal: Journal of Clinical Medicine
Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring
doi: 10.3390/jcm10112326
Figure Lengend Snippet: Boxplots showing initial axial stiffness slope. 1: Sacroiliac (SI) screw; 2: SI screw plus supra-acetabular external fixator; 3: SI screw plus anterior plate; 4: SI screw plus retrograde transpubic screw; 5: S1/S2 ala–ilium screws. Asterisks above the boxplots indicate significant differences.
Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm
Techniques:
Journal: Journal of Clinical Medicine
Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring
doi: 10.3390/jcm10112326
Figure Lengend Snippet: Boxplots showing cycles to failure. 1: Sacroiliac (SI) screw; 2: SI screw plus supra-acetabular external fixator; 3: SI screw plus anterior plate; 4: SI screw plus retrograde transpubic screw; 5: S1/S2 ala–ilium screws. Asterisks above the boxplots indicate significant differences.
Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm
Techniques:
Journal: Journal of Clinical Medicine
Article Title: Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring
doi: 10.3390/jcm10112326
Figure Lengend Snippet: Failure modes (red circle) in groups 1 (SI screw) ( A ), 2 (SI screw plus supra-acetabular external fixator) ( B ), 3 (SI screw plus plate fixation) ( C ), 4 (SI screw plus a retrograde transpubic screw) ( D ), and 5 (S1/S2 ala–ilium screws) ( E ) after reaching test stop criterion of 30 mm machine actuator displacement.
Article Snippet: The fracture of the anterior ring in group 4 was fixed with a 4.5 × 70 mm
Techniques:
Journal: Journal of Clinical Medicine
Article Title: Triangular Screw Placement to Treat Dysmorphic Sacral Fragility Fractures in Osteoporotic Bone Results in an Equivalent Stability to Cement-Augmented Sacroiliac Screws—A Biomechanical Cadaver Study
doi: 10.3390/jcm14051497
Figure Lengend Snippet: ( A ) Schematic drawing of the triangular fixation of the sacrum. Two oblique screws in the S1 vertebra and a transiliosacral screw in the S2 vertebra. ( B ) Schematic drawing of the additional cement augmentation of the oblique screws in the S1 vertebra. Dotted red line represents the fracture-lines.
Article Snippet: Group 1: In this group, we stabilized the sacral fracture using two partially threaded sacroiliac screws from both sides, oblique inverted (cannulated, partial threaded steel screw 7.3 mm, DePuy Synthes, Raynham, MA, USA), and a fully threaded